Specification:
CZPT: | IEC60034 | ||
Frame Measurement: | H80-H355 | ||
Electrical power: | .seventy five-300KW | ||
Rated Voltage: | 380V,400V,415V | ||
Rated Frequency: | 50HZ,60HZ | ||
Poles: | four | ||
Pace: | 1000-300r/min | ||
Existing: | 1.five-40A | ||
Efficiency Course: | IE2 | ||
Insulation Class: | F | ||
Defense Class: | IP54 IP55 | ||
Cooling Method: | IC411 | ||
Ambient Temperature: | -15°C-+40ºC | ||
Mounting: | B3,B35 | ||
Obligation: | S1 | ||
Body Content: | Cast Iron/Aluminum | ||
Terminal Box: | Prime or Facet | ||
Altitute: | ≤1000m | ||
Certification: | CE 3C CZPT |
Description:
The lengthen shaft motor adopts the style technologyand is made of warmth-resistant insulating resources. It can guarantee the safe procedure of the motor in higher-temperature enviroment CZPT ageing and burning. Its motor functionality is made in accordance to the characteristics of supporter and pumb load, which can conserve power and adopt reinforced insulation to make sure trustworthy insulation and boost service daily life.
Announcements:
1.Make sure you confirm no matter whether the look of the motro is broken prior to ues? Is there any oil leakage?
2.Remember to validate the voltage of the motor. Voltage regulator can be set up whne voltage is unstable.
three.You should confirm regardless of whether the speciation of the motor obtained is consistent with the style specification.
4.Make sure you make positive that the body is mounted to steer clear of loosening throughout operation.
5.If sprocket, pulley,coupling are utilized and other components must be put in according to pertinent regulation.
six.The lubricating grease has been set into the physique of the decelerating motor, and the lubricating oil can not be modified for 12000 hours.
7.When the motor is running, the rated current shall not exceed the recent benefit indicated on the motor nameplate.
eight.Make sure you shell out consideration to the surrounding temperature, humidity, pH and other issues.
9.If it is not mounted or operated in the proper way, it may trigger significant harm to the motor.
10.In the course of routine maintenance or disassembly, it is necessary to affirm that the external power supply is totally folded absent from the motor.
11.The protection safety system ought to be mounted to ensure the security of operation.
12.The motor demands grounding wire, remember to refer to pertinent power distribution.
thirteen.Please confirm that all set up areas and transmission accessories are fastened accurately beforestarting the deceleration motor.
14.If the motor is pushed with frequency converter at low velocity, it is required to put in the auxiliary cooling fan.
fifteen.Please tell the technical office of our factory when the motor is mounted vertically.