Frequency Inverter 3 pH 11kw Chinese AC Drive 60Hz to 50Hz Speed Controller Motor

Frequency Inverter 3 pH 11kw Chinese AC Drive 60Hz to 50Hz Speed Controller Motor

2.1 Naming and nameplate identification
2.1.one Naming rule
JAC200 11KW

 

Identification Voltage level
4 three-period 380V
S2 Single-period 220V

 

Identification Adaptive motor kind
G CZPT sort

 

Identification .four .seventy five four hundred
Adaptive motor(KW) .four .seventy five four hundred

two.2 Introduction of a variety of components of the converter
The composition types of JAC580N sequence converter are the plastic and metallic. The exterior diagram is shown beneath.

two.3 Fundamental specialized specification 
Desk two-1 CZPT specification of 580N sequence frequency converter

Item Specification
CZPT functions Highest frequency Vector control: ~500Hz V/F management: ~500Hz
Provider frequency .8kHz~12kHz
The provider frequency is instantly altered primarily based on the load attributes.
Enter frequency
resolution
Digital environment: .01Hz
Analog location: highest frequency x .571%
Manage method • Open-loop vector control (SVC)
• Closed-loop vector control (FVC)
• Voltage/Frequency (V/F) handle
CZPTting torque • G kind: .5 Hz/150% (SVC) Hz/a hundred and eighty% (FVC)
• P variety: .5 Hz/one hundred%

Basic features

Velocity range one:one hundred  (SVC) one:one thousand  (FVC)
Continual-velocity precision ± .five%  (SVC) ± .02%  (FVC)
Overload capacity • G kind:60s for one hundred fifty% of the rated recent
• P kind: 60s for a hundred and twenty% of the rated current.
Torque boost • Fixed boost
• CZPTized improve .one%-thirty.%
V/F curve • Straight-line V/F curve
• Multi-stage V/F curve
•N-energy V/F curve (one.2-energy, 1.four-electrical power, one.6-electricity, ,one.eight-power, sq.)
V/F separation Two types: full separation 50 % separation
Acceleration /deceleration curve • Straight-line ramp
• S-curve ramp
Four teams of acceleration/deceleration time with the
variety of .-6500.0s
DC braking DC braking frequency: .00Hz~greatest frequency
Braking time: .0s~36.0s
Braking action current value: .%-a hundred.%
JOG handle JOG frequency assortment: .00-50.00 Hz
JOG acceleration/deceleration time: .-6500.0s
Procedure Command source Procedure panel, manage terminal and serial communication port are provided
Swap in various methods
Frequency supply Numerous frequency resources: digital reference, analog voltage reference, analog recent reference, pulse reference and serial port reference. The switching can be performed in numerous techniques
Auxiliary frequency source ten types of auxiliary frequency supply. The auxiliary frequency jog and frequency synthesis can be achieved flexibly
Input terminal CZPTs:
seven electronic input terminals, amongst which a single help highest high-velocity pulse input of 100kHz
2 analog enter terminals, between which one only supports voltage input of ~10V and the other supports voltage enter of ~10V or current input of 4 ~20mA
Enlargement capability:
three electronic enter terminals
1 analog enter terminal, which supports voltage input of -10V ~10V and supports PT100/PT1000
Output terminal CZPTs:
one large-speed pulse output terminal (The open up collector sort is optional), supporting ~100kHz square sign output
one electronic output terminal
1 relay output terminal
1 analog output terminal, supporting existing output of ~20mA or voltage output of ~10V
Growth ability:
1 digital output terminal
one relay output terminal
1 analog output terminal, supporting present output of ~20mA or voltage output of ~10V
Show and keyboard procedure LED display Exhibit the parameter
Essential lock and perform choice Understand partial or all essential lock and determine the action range of some keys to prevent misoperation
Security purpose Short circuit take a look at of electrified motor, input/output default period defense, overcurrent defense, overvoltage protection, undervoltage safety, overheat protection, overload defense, and so forth.

 

Frequency Inverter 3 pH 11kw Chinese AC Drive 60Hz to 50Hz Speed Controller Motor